FS#8047 — vss-2-6k

Attached to Project— Network and racks
Incident
Paris
CLOSED
100%
Le niveau de cpu de ce routeur est élevé.
Cela cause des pertes de ping.
Nous investiguons.
Date:  Monday, 11 February 2013, 18:24PM
Reason for closing:  Done
Comment by OVH - Monday, 11 February 2013, 18:23PM

Nous retirons les annonces ipv6 sur les vlans clients pour soulager le routeur.


vss-2-6k#conf t
Enter configuration commands, one per line. End with CNTL/Z.
vss-2-6k(config)#interface Vlan859
vss-2-6k(config-if)# ipv6 nd ra suppress
vss-2-6k(config)#interface Vlan860
vss-2-6k(config-if)# ipv6 nd ra suppress
vss-2-6k(config)#interface Vlan861
vss-2-6k(config-if)# ipv6 nd ra suppress



Comment by OVH - Monday, 11 February 2013, 18:24PM

Le routeur est à présent stable.

vss-2-6k#sh processes cpu sorted
CPU utilization for five seconds: 74%/23%; one minute: 68%; five minutes: 72%
PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process
3 14748 43110 342 16.29% 11.95% 3.51% 23 SSH Process
362 866324308 21232715 40801 6.54% 5.81% 5.16% 0 CEF: IPv4 proces
11 1093090180 867509502 1260 3.67% 6.45% 7.61% 0 ARP Input
566 311379740 176960817 1759 3.51% 2.41% 3.62% 0 BGP Router