FS#8136 — bhs-s6-6k

Attached to Project— Reseau Internet et Baies
Maintenance
Beauharnois
CLOSED
100%
Nous avons rencontré un problème sur la TCAM de la sup du routeur:

Feb 27 18:23:32 bhs-s6-6k 628: Feb 27 18:21:34 GMT: %DIAG-3-TEST_FAIL: Module 5: TestL3TcamMonitoring{ID=34} has failed. Error code = 0x43 (DIAG_INSERT_FIB_ENTRY_V4_ERROR)
Feb 27 18:23:32 bhs-s6-6k 628: Feb 27 18:21:34 GMT: %DIAG-3-TEST_FAIL: Module 5: TestL3TcamMonitoring{ID=34} has failed. Error code = 0x43 (DIAG_INSERT_FIB_ENTRY_V4_ERROR)

Nous routons le trafic sur bhs-s5-6k et redemarrons bhs-s6-6k.
Date:  Thursday, 28 February 2013, 18:25PM
Reason for closing:  Done
Comment by OVH - Thursday, 28 February 2013, 18:25PM

Done.

La FIB exception n'est plus présente :

bhs-s6-6k#sh platform hardware cef exception status
Current IPv4 FIB exception state = FALSE
Current IPv6 FIB exception state = FALSE
Current MPLS FIB exception state = FALSE
Current EoM/VPLS FIB TCAM exception state = FALSE